Digital Oscilloscopes
250MHz, 25GS/s, 32kBytes, RS-232C,
USB, Printer, FFT
| Features/Functions |
DS-1080 |
DS-1150 |
Ds-1250 |
| Bandwidth |
80MHz |
150MHz |
250MHz |
| Max.
sampling rate |
25GS/s
equivalent-time |
| per
channel |
200MS/s
real-time |
| Display |
5.7
monochrome LCD |
| No.
of channel |
Dual
digitizer |
| Record
lenght |
10kBytes |
32kBytes |
| Peak
detection |
10ns |
| Aotu
measument |
10
parameters |
| FFT
function |
Standard |
| Interface |
USB,
RS-232C, Printer |
OS-5030
30MHz 2ch dual trace

|
- DC to 30MHz BandWith, 2CH
- dual trace
- 6' Rectangular CRT with
internal graticule
- Sensitivity 1 mV / div
ALT. triggering function(Vert
Mode)
- CH2 Polarity inversion
switch
- High sensitivity X - Y
mode
- Sweep magnification(X10)
- TV sync. separator circuit
for stable TV signal observation
- 400V maximum. input voltage
|
OS-5020/OS-5020C
20MHz 2ch dual trace

|
- DC to 20MHz BandWith, 2CH
- dual trace
- 6' Rectangular CRT with
internal graticule
- Sensitivity 1 mV / div
- ALT. triggering function(Vert
Mode)
- CH2 Polarity inversion
switch
- High sensitivity X - Y
mode
- Sweep magnification (X
10)
- TV sync. separator circuit
for stable TV signal observation
- 400V maximum. input voltage
- Component test funtion
(OS-5020C Only)
|
OS-502OG
20MHZ 2ch dual trace
Built - in 1 MHz function
generator

|
- DC to 20MHz, 2CH - dual
trace
- Built - in 1 MHz function
generator with TTL output
- CH2 polarity inversion
switch
- High sensitivity X - Y
mode
- Vertical deflection magnification,
X5
- Sensitivity is 1 mV / div
- Variable hold - off for
observation of wave forms with complex periods
- Employment of TV sync.
separator circuit allows the instrument to observe TV signals
stably
- Sweep magnification, X5
|
| |
OS-5100
100MHz 2ch dual trace

|
- 6' large size high luminance
CRT
Wider than specified frequency
response
- Signal delay with delay
line useful for observation of signal start point
- ALT. Triggering function(Vert
Mode)
- Auto focusing according
to the change of intensity
- Drift compensation circuit
employed in vertical amplifier for low drift
- Jifterless and high trigger
sensitivity
- TV sync. separation and
hold-off circuit useful in video signal observation
|
OS-5060A
60MHz 2ch dual trace

|
- 6' large size, high luminance
CRT
- Wide dynamic range even
at high frequencies
- High deflection factor
- Max. sweep time of lOns
I div,
- Variable hold - off function
- Delay sweep function
- Level control allows superior
triggering
- TV synch. circuit
- X -Y operation
- Signal delay line
- Scale illumination
|
OS-5040A
40MHz 2ch dual trace

|
- 6' large size high luminance
CRT
- Wide dynamic range even
at high frequencies
- High deflection factor
- Max. sweep time of 20ns
/ div
- Variable hold - off function
- Delay sweep function
- Level control allows supedor
tiriggering
- TV synch. circuit
- X -Y operation
- Signal delay line
- Scale illumination
|
For more information please go to www.ezdgt.com |
|