X BAND 
  • (10.300 GHz)
  • (MICROWAVE TRAINING SYSTEM)

   BASIC EXPERIMENTS
MT-
1000VM 
MT-
100M1
MT-
1000M
MT-
1000
1
*
*
*
*
2
*
*
*
*
3
*
*
*
*
4
*
*
*
*
5
*
*
*
*
6
*
*
*
*
7
*
*
*
*
8
*
*
*
*
9
*
*
-
*
10
*
*
-
*
11
*
*
-
*
12
*
*
*
*
13
*
*
*
*
14
*
*
*
*
15
*
*
*
*
16
-
-
-
*
Experimentation
1
Frequency, Wavelength and attenuation measurement
2
SWR measurement
3
Power measurement
4
Impedance measurement, smith chart
5
Study of a gunn diode
6
Study of the doppler effect
7
Microwave detector
8
Horn antenna measurement
9
Parabolic antenna measurement
10
Slot antenna measurement
11
Gain measurement with 3 type of antenna
12
Microwave propagation
13
Microwave modulation
14
Study of waveguide junction
15
Study of the directional coupler
16
TV communication with microwave link
PN 1003 Parabolic Antenna
  • Parabolic Antenna PN 1003 consists of Parabolic Dish and Waveguide Rear Feed. Parabolic Dish is made of aluminium.
PN 1010/01 Waveguide Bend
  • E-BEND
  • E-Bend PN 1010/01 is E-plane waveguide bend with 30mm. Radial and 90° angle.
PN 1010/02 Waveguide Bend
  • H-BEND
  • H-Bend PN 1010/02 is H-plane waveguide bend with 30 mm. radial and 90° angle.
PN 1018B SWR-Meter
  • The SWR Meter type PN 1018 is a low noise 1000 Hz tuned amplifier/voltmeter. To avoid hum caused by ground loop currents the measuring circuit is completely isolated from mains ground.
PN 1021
  • The Frequency Meter consists of a coaxial cavity with a tuning plunger and micro-meter readout in mm. which is converted to frequency by data sheet. The cavity is coupled to a passing waveguide via hole in the narrow wall of waveguide when the frequency of signal in passing waveguide is the same as the resonant frequency of the cavity, an amount of power will be removed from the waveguide. This means an additional transmission loss at the resonant frequency (a “dip” in transmitted).
  • Which can be observed on a detecting instrument connected to the passing waveguide. Alternatively, the cavity can be connected to a crystal detector. Which will give maximum current at the resonant frequency.
PN 1022 Variable Attenuator
  • The attenuation as a function of the micrometer reading is given on the calibration chart.
PN 1024B Gunn Oscillator Power Supply
  • The Power Supply PN 1024 is specially designed to supply Gunn Oscillator. The power supply is also generated with a 1 KHz output for modulation.
PN 1025 Solid-State X-Band Gunn Oscillator
  • It consists of a varactor  tuned Gunn Oscillator providing 60Mhz minimum electronic tuning a ferrite circulator and mixer assembled into a compact waveguide package. The Schottky barrier mixer diodes are field replaceable.
PN 1002 Horn Antenna
  • Horn Antenna PN 1002 has exponentially flared guide wall to give a proper matching between the waveguide and free space.
  • Receiver
  • Transmitter
  • Television communication